8654 Series Quick Shutoff Valve
The Young & Franklin 8654 Series Quick Shut-Off Valve is a high speed, solenoid operated shutoff valve and is designed for use on combustion or gas turbine engines. There is a single main stage inlet port, an outlet port, and pilot stage plus a vent port. The valve can be used to rapidly shut off flow and isolate the source from the turbine engine, and bi‐directional sealing in closed position prevents backflow from the combustion chamber. The valve can be used with air and natural gas and are NACE compliant.
- Specs
- Applications
- Documents
Nominal Valve Size | DN 80; 3” | ||||||||
Estimated Dry Weight | Carbon Steel: 3” Valve: 127 lbs. Double Block & Bleed: 276 lbs.Stainless Steel: 3” Valve: 129 lbs. Double Block & Bleed: 281 lbs. | ||||||||
Shut‐off Time | < 150 ms | ||||||||
Opening Time | 3-5 s | ||||||||
Operating Pressure (min) | 130 psi (9 bar) | ||||||||
Operating Pressure (max) | 510 psi (35 bar) | ||||||||
Valve Flange Size | ASME B16.5, Class 300, Raised‐Face | ||||||||
Valve Material | Carbon Steel (NACE compliant trim), Stainless Steel (optional) | ||||||||
Leakage Rate (bidirectional) | Class VI per ANSI/FCI 70‐2 (0.9 mL/min, 6 bubbles/min) | ||||||||
Flow Rating | Cv = 210 | ||||||||
Media Temperature | ‐4° to +392°F (‐20° to +200°C) | ||||||||
Ambient Temperature | ‐40° to +212°F (‐40° to +100°C) | ||||||||
Solenoid Voltage | 125 VDC (90 to 150 VDC), 24 VDC (18 to 32 VDC) | ||||||||
Closed Proximity Sensor | SPDT Proximity Switch | ||||||||
Maintenance Interval | 4 years | ||||||||
Certifications | Cls I Div 1, Grp B, C & D, T3 Ex db IIB T3 Gb IP65 |